230Vac powered 0.1second to 4 minute non-retriggerable delayed-off timer board module with mains rated relay output. When activated the relay turns on for the user-set time period and then turns off.
The timer is triggered by closing the low voltage Start Input (using for example a volt-free push button or relay contact closure).
This is a non-retriggerable timer - the relay will always turn off at timeout. Any further Start Input triggers received during countdown or it being in an open or closed state at timeout are ignored. The timer resets on timeout and is ready for a new trigger. The Start Input must go open circuit and be closed again to register a new trigger input.
Optional Power-Start mode. Start input disabled. Relay turns on and delay countdown commences immediately power is applied to the board. Relay turns off at timeout. Power must be removed and reapplied for a fresh countdown to commence. Power-Start mode is set using a header jumper.
Scale switch selects one of two delay ranges, 0.1 to 24 seconds or 1 second to 4 minutes, giving more precise and easier time setting using the onboard potentiometer (header pins allow the use of user-supplied external potentiometers if required).
An LED indicates that the relay is active.
2023 Product Update: New improved DIN-Rail size board with wider time range and easier setting.
A TRIAC output version of this board is available (Order Code CI018)
Specifications| Operating Voltage | 230Vac mains |
| Current Consumption | 30mA min. - 85mA max. |
| Time Delay - Scale A | 0.1 to 24 seconds |
| Time Delay - Scale B | 1 second to 4 minutes |
| Output | 1 x SPDT Relay |
| Maximum Output Load (Resistive) | Up to 250Vac or 28Vdc @ 7 Amps max. resistive (2A inductive) (Relay Datasheet) |
| Relay Connections | NO, NC, C (Relay FAQ) |
| Dimensions (WxDxH) | ~ 72 x 76 x 32 mm |
| DIN-RAIL Mount | C7565 |
| Enclosure | WCAH2853 |
| Product Format | PRE-ASSEMBLED Electronic Module Product Format Info |
| WARNING | Product operates at mains voltage and is not suitable for children. An isolating enclosure is required (not included). Installation, testing and commissioning should be performed by a competent person. Mains Electricity Info |