12Vdc powered 1 to 180 Second 'Disconnection' or 'Turn-Off' or 'Instant-On and Hold, Delayed-Off' timer module with a mains rated relay output.
Timer is activated using the Start Input, using for example a push button or relay contact closure (takes the input to ground). When activated, the relay turns on but the user-set delay countdown does NOT commence. This state is maintained while the trigger signal is present. Loss of trigger signal starts the delay countdown. Relay releases at end of delay period and timer returns to it's waiting state.
If a fresh Start input is received at any point during the delay countdown, the relay will remain held on for as long as the trigger input is present. On loss of the Start input, the delay period recommences for the full time period set at the end of which the relay turns off. The unit then resets, ready for a fresh Start input.
The delay period is adjustable from 1 to 180 seconds using the onboard potentiometers (header pins allow the use of user-supplied external potentiometers if required).
Applications: Allows a pump or fan to remain on for a while after a sensor detects a preset level, to prevent cycling.
FeaturesSupply Voltage | 12V dc |
Power Supply Options | Power Supply Module: CFE103 or UK Plug Power Supply: 660.446UK with connector 777.001UK |
Current Consumption | ~ 50mA |
Output | 1 x SPDT Relay |
Maximum Output Load (Resistive) | Up to 240Vac or 28Vdc @ 5 Amps max. (Relay Datasheet) |
Relay Connections | NO, NC, C (Relay FAQ) |
Dimensions (WxDxH) | ~ 44 x 76 x 30 mm |
Enclosure | WCAH2853 |
Product Format | PRE-ASSEMBLED Electronic Module Product Format Info |